Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 1
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Determination of Prostaglandins in the Colostrum of Dairy Cattle by Thermospray High-Performance Liquid Chromatography-Mass Spectrometry. OAK
FUKUSHIMA, Michihiro; NAKANO, Masuo; ENDO, Tsuyoshi; NEGISHI, Takashi; 福島, 道広.
A thermospray high-performance liquid chromatography-mass spectrometry (TSP HPLC-MS) method is described for the analysis of prostaglandins (PGs) E1 and E2, which have several physiological actions at the trace level. HPLC separation was carried out on a reversed-phase column by using 50mM ammonium acetate (pH 4.5)-acetonitrile (7:3, v/v) as the mobile phase at a flow rate of 1.0ml/min. In MS detection, the vaporizer temperature was set at 220°C and the ion-source block temperature at 264°C. The mass spectra obtained from PGs typically exhibited the [M+NH4]+ ion (5 to 30% relative intensity) and several fragment ions due to sequential losses of water from both the [M+H]+ and [M+NH4]+ ions. PGE1 (46.9ppb) and PGE2 (1.9ppb) in the colostrum of dairy cattle...
Palavras-chave: Thermospray liquid chromatography-mass spectrometry; Prostaglandin; Colostrum; Dairy cattle.
Ano: 1993 URL: http://ir.obihiro.ac.jp/dspace/handle/10322/4042
Registros recuperados: 1
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional